Clamp sensors

Clamp tester digital - leakage current AC 0.01mA-400A

MCM-400.0.0
MULTI
Available
Type
Digital
Inside diameter (mm)
40
Dimensions (mm)
69 x 207 x 33
Operation temperature
0 C +40 C 70%RH without condensation
Applicable current AC (A)
400
Power Supply Voltage (V)
6LR61 or AC adapter
Leakage current AC (mA)
0,01

Product available on request


Catalog

Clamp type current sensor AC 10A

MCL-800IR.0.0
MULTI
Available
Rated Voltage Un AC (V)
500
Type
Digital
Inside diameter (mm)
80
Housing
Split type
Dimensions (mm)
71 x 315 x 37
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
10
Power Supply Voltage (V)
LR03, AM-3 o AAA x3
Leakage current AC (mA)
0,001

Product available on request


Catalog

Clamp type current sensor AC 500A

MCL-500IR.0.0
MULTI
Available
Rated Voltage Un AC (V)
500
Type
Digital
Inside diameter (mm)
40
Housing
Split type
Dimensions (mm)
70 x 223 x 34
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
500
Power Supply Voltage (V)
LR03, AM-3 o AAA x3
Leakage current AC (mA)
0,01

Product available on request


Catalog

Clamp tester digital-leakage current AC 0.01mA-300A

MCL-400IR.0.0
MULTI
Available
Rated Voltage Un AC (V)
500
Type
Digital
Inside diameter (mm)
40
Dimensions (mm)
70 x 223 x 34
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,065
Applicable current AC (A)
300
Power Supply Voltage (V)
1,5V (AAA, UM-4)x3 or AC adapter (Optional)
Leakage current AC (mA)
0,01

Product available on request


Catalog
Datasheet

Clamp tester digital-leakage current AC 0.1mA-400A

MCL-400D.0.0
MULTI
Available
Rated Voltage Un AC (V)
600
Type
Digital
Inside diameter (mm)
40
Dimensions (mm)
69 197 32
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
400
Power Supply Voltage (V)
1,5V (AM-4, LR03, AAA) 2
Leakage current AC (mA)
0,1
Resistance (Mohm)
0,002

Product available on request


Catalog
Datasheet

Clamp tester analogic-leakage current AC 0.1mA-500A

MCL-350.0.0
MULTI
Available
Rated Voltage Un AC (V)
500
Type
Analog
Inside diameter (mm)
40
Dimensions (mm)
65 210 34
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
500
Power Supply Voltage (V)
1,5V (AM-4, LR03, AAA) 2
Leakage current AC (mA)
0,1
Resistance (Mohm)
0,001

Product available on request


Catalog
Datasheet

Clamp tester digital AC 3000A

MCL-3000D.0.0
MULTI
Available
Type
Digital
Inside diameter (mm)
108 x 128
Dimensions (mm)
194 x 341,5 x 52
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
3000
Power Supply Voltage (V)
1,5V (AAA, UM-4)x 2

Product available on request


Catalog
Datasheet

Clamp tester digital-leakage current AC 0.1mA-3000A

MCL-1100D.0.0
MULTI
Available
Type
Digital
Inside diameter (mm)
108 x 128
Dimensions (mm)
194 x 341,5 x 52
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
3000
Power Supply Voltage (V)
1,5V (AAA, UM-4)x 2
Leakage current AC (mA)
0,1

Product available on request


Catalog
Datasheet

Clamp tester digital-leakage current AC/DC 0.01mA-10A

M-730.0.0
MULTI
Available
Type
Digital
Inside diameter (mm)
30
Dimensions (mm)
78 155 32(acquisitore) 33 170 24(sensore)
Operation temperature
0 C +50 C 80%RH without condensation
Applicable current AC (A)
10
Power Supply Voltage (V)
LR6, AM-3 o AA 4
Applicable current DC (A)
10
Leakage current AC/DC (mA)
0,01

Product available on request


Catalog
Datasheet

Clamp tester digital-leakage current AC/DC 0.01mA-10A

M-700.0.0
MULTI
Available
Type
Digital
Inside diameter (mm)
5
Dimensions (mm)
78x155 32(acquisitore) 19 133 28 (sensore)
Operation temperature
0 C +50 C 80%RH without condensation
Applicable current AC (A)
10
Power Supply Voltage (V)
LR6, AM-3 o AA 4
Applicable current DC (A)
10
Leakage current AC/DC (mA)
0,01

Product available on request


Catalog
Datasheet

Clamp tester analogic AC 600A 600VAC/60VDC 100kohm

M-3000.0.0
MULTI
Available
Rated Voltage Un AC (V)
600
Rated Voltage Un DC (V)
60
Type
Analog
Inside diameter (mm)
40
Dimensions (mm)
69 210 34
Operation temperature
0 C +40 C 80%RH without condensation
Frequency f (kHz)
0,060
Applicable current AC (A)
600
Power Supply Voltage (V)
1,5V (AM-4, LR03, AAA) 2
Resistance (Mohm)
0,001

Product available on request


Catalog
Datasheet

Clamp tester digital AC/DC 400A 600VAC/DC 1kohm

M-290RMS.0.0
MULTI
Available
Rated Voltage Un AC (V)
600
Rated Voltage Un DC (V)
600
Type
Digital
Inside diameter (mm)
30
Dimensions (mm)
45 180 24
Operation temperature
0 C +40 C 80%RH without condensation
Applicable current AC (A)
400
Power Supply Voltage (V)
1,5V (AM-4, LR03 o AAA) 3
Applicable current DC (A)
400

Product available on request


Catalog
Datasheet

Clamp tester digital AC/DC 1000A 500VAC/DC 600ohm

M-280.0.0
MULTI
Available
Rated Voltage Un AC (V)
500
Rated Voltage Un DC (V)
500
Type
Digital
Inside diameter (mm)
30
Dimensions (mm)
44,5 177 24
Operation temperature
0 C +40 C 80%RH without condensation
Applicable current AC (A)
1000
Power Supply Voltage (V)
LR-44 2
Resistance (Mohm)
0,001
Applicable current DC (A)
1000

Product available on request


Catalog
Datasheet

Clamp tester digital AC/DC 2000A 600VAC/DC 40Mohm

M-270.0.0
MULTI
Available
Rated Voltage Un AC (V)
600
Rated Voltage Un DC (V)
600
Type
Digital
Inside diameter (mm)
55
Dimensions (mm)
85 240 34
Operation temperature
0 C +40 C 80%RH without condensation
Applicable current AC (A)
2000
Power Supply Voltage (V)
1,5V (AM-4, LR03, AAA) 2
Resistance (Mohm)
40
Applicable current DC (A)
2000

Product available on request


Catalog
Datasheet

Clamp tester digital AC/DC 2000A 600VAC/DC 40Mohm

M-260.0.0
MULTI
Available
Rated Voltage Un AC (V)
600
Rated Voltage Un DC (V)
600
Type
Digital
Inside diameter (mm)
55
Dimensions (mm)
85 240 34
Operation temperature
0 C +40 C 80%RH without condensation
Applicable current AC (A)
2000
Power Supply Voltage (V)
1,5V (AM-4, LR03, AAA) 2
Resistance (Mohm)
40
Applicable current DC (A)
2000

Product available on request


Catalog
Datasheet

Filter by

Manufacturer
more... less
Rated Voltage Un AC (V)
500 7000
Rated Voltage Un DC (V)
60 600
Applicable current AC (A)
1 3000
Applicable current DC (A)
10 2000
Type
more... less
Inside diameter (mm)
5 108128
Product added to wishlist
Product added to compare.